77 lines
2.5 KiB
Arduino
Raw Normal View History

2019-05-23 16:51:24 -05:00
/*
2019-05-23 16:58:33 -05:00
MQUnifiedsensor Library - reading an MQ8
2019-05-23 16:51:24 -05:00
2019-05-23 16:58:33 -05:00
Demonstrates the use a MQ8 sensor.
2019-05-23 16:51:24 -05:00
Library originally added 01 may 2019
by Miguel A Califa, Yersson Carrillo, Ghiordy Contreras, Mario Rodriguez
Added example
modified 23 May 2019
by Miguel Califa
2020-03-26 13:09:10 -05:00
Updated library usage
modified 26 March 2020
by Miguel Califa
2019-05-23 16:51:24 -05:00
This example code is in the public domain.
*/
//Include the library
2019-05-19 13:27:00 -05:00
#include <MQUnifiedsensor.h>
2019-05-23 16:51:24 -05:00
//Definitions
2020-03-26 13:09:10 -05:00
#define placa "Arduino UNO"
#define Voltage_Resolution 5
2019-05-23 16:51:24 -05:00
#define pin A0 //Analog input 0 of your arduino
2020-03-26 13:09:10 -05:00
#define type "MQ-8" //MQ8
#define ADC_Bit_Resolution 10 // For arduino UNO/MEGA/NANO
//#define calibration_button 13 //Pin to calibrate your sensor
2019-05-19 13:27:00 -05:00
2019-05-23 16:51:24 -05:00
//Declare Sensor
2020-03-26 13:09:10 -05:00
MQUnifiedsensor MQ8(placa, Voltage_Resolution, ADC_Bit_Resolution, pin, type);
2019-05-23 16:51:24 -05:00
void setup() {
2020-03-26 13:09:10 -05:00
//Init the serial port communication - to debug the library
2019-08-14 22:31:06 -05:00
Serial.begin(9600); //Init serial port
2019-05-19 13:27:00 -05:00
2020-03-26 13:09:10 -05:00
//Set math model to calculate the PPM concentration and the value of constants
2020-03-26 22:18:07 -05:00
MQ8.setRegressionMethod(1); //_PPM = a*ratio^b
2020-03-26 13:09:10 -05:00
MQ8.setA(976.97); MQ8.setB(-0.688); // Configurate the ecuation values to get H2 concentration
/*
2020-03-26 13:09:10 -05:00
Exponential regression:
GAS | a | b
H2 | 976.97 | -0.688
LPG | 10000000 | -3.123
CH4 | 80000000000000 | -6.666
CO | 2000000000000000000 | -8.074
Alcohol | 76101 | -1.86
*/
2020-03-26 13:09:10 -05:00
// Calibration setup
MQ8.setR0(1);
/*
//If the RL value is different from 10K please assign your RL value with the following method:
MQ8.setRL(10);
*/
/***************************** MQ Init ********************************************/
//Remarks: Configure the pin of arduino as input.
/************************************************************************************/
MQ8.init();
/***************************** MQ Init ********************************************/
//Input: setup flag, if this function are on setup will print the headers (Optional - Default value: False)
//Output: print on serial port the information about sensor and sensor readings
//Remarks: Configure the pin of arduino as input.
/************************************************************************************/
MQ8.serialDebug(true);
2019-05-19 13:27:00 -05:00
}
2020-03-26 13:09:10 -05:00
void loop() {
MQ8.update(); // Update data, the arduino will be read the voltage on the analog pin
MQ8.readSensor(); // Sensor will read PPM concentration using the model and a and b values setted before or in the setup
MQ8.serialDebug(); // Will print the table on the serial port
delay(500); //Sampling frequency
}