@ -93,8 +93,8 @@ void MQUnifiedsensor::serialDebug(bool onSetup)
|
||||
Serial.print("|"); Serial.print(_adc); Serial.print("| v = ADC*"); Serial.print(_VOLT_RESOLUTION); Serial.print("/"); Serial.print(pow(2, _ADC_Bit_Resolution)); Serial.print(" | "); Serial.print(_sensor_volt);
|
||||
Serial.print(" | RS = ((" ); Serial.print(_VOLT_RESOLUTION ); Serial.print("*RL)/Voltage) - RL| "); Serial.print(_RS_Calc); Serial.print(" | Ratio = RS/R0| ");
|
||||
Serial.print(_ratio); Serial.print( " | ");
|
||||
if(_regressionMethod != 1) Serial.println("ratio*a + b");
|
||||
else Serial.print("a*ratio^b");
|
||||
if(_regressionMethod == 1) Serial.println("ratio*a + b");
|
||||
else Serial.print("pow(10, (log10(ratio)-b)/a)");
|
||||
Serial.print(" | "); Serial.print(_PPM); Serial.println(" |");
|
||||
}
|
||||
}
|
||||
@ -110,7 +110,11 @@ float MQUnifiedsensor::validateEcuation(float ratioInput)
|
||||
//Serial.print("b: "); Serial.println(_b);
|
||||
//Usage of this function: Unit test on ALgorithmTester example;
|
||||
if(_regressionMethod == 1) _PPM= _a*pow(ratioInput, _b);
|
||||
else _PPM= _a*ratioInput + _b;
|
||||
else
|
||||
{
|
||||
double ppm_log = (log10(_ratio)-_b)/_a; //Get ppm value in linear scale according to the the ratio value
|
||||
_PPM = pow(10, ppm_log); //Convert ppm value to log scale
|
||||
}
|
||||
//Serial.println("Regression Method: "); Serial.println(_regressionMethod);
|
||||
//Serial.println("Result: "); Serial.println(_PPM);
|
||||
return _PPM;
|
||||
@ -123,7 +127,11 @@ float MQUnifiedsensor::readSensor()
|
||||
_ratio = _RS_Calc / this->_R0; // Get ratio RS_gas/RS_air
|
||||
if(_ratio <= 0) _ratio = 0; //No negative values accepted or upper datasheet recomendation.
|
||||
if(_regressionMethod == 1) _PPM= _a*pow(_ratio, _b);
|
||||
else _PPM= _a*_ratio + _b;
|
||||
else
|
||||
{
|
||||
double ppm_log = (log10(_ratio)-_b)/_a; //Get ppm value in linear scale according to the the ratio value
|
||||
_PPM = pow(10, ppm_log); //Convert ppm value to log scale
|
||||
}
|
||||
if(_PPM < 0) _PPM = 0; //No negative values accepted or upper datasheet recomendation.
|
||||
//if(_PPM > 10000) _PPM = 99999999; //No negative values accepted or upper datasheet recomendation.
|
||||
return _PPM;
|
||||
|