/* MQUnifiedsensor Library - calibrating an MQ2 to MQ9 Demonstrates the use a MQ2 sensor. Library originally added 01 may 2019 by Miguel A Califa, Yersson Carrillo, Ghiordy Contreras, Mario Rodriguez Added example modified 27 May 2019 by Miguel Califa This example code is in the public domain. */ //Include the library #include //Definitions #define pin2 A2 //Analog input 2 of your arduino #define pin3 A3 //Analog input 3 of your arduino #define pin4 A4 //Analog input 4 of your arduino #define pin5 A5 //Analog input 5 of your arduino #define pin6 A6 //Analog input 6 of your arduino #define pin7 A7 //Analog input 7 of your arduino #define pin8 A8 //Analog input 8 of your arduino #define pin9 A9 //Analog input 9 of your arduino //Declare Sensor MQUnifiedsensor MQ2(pin2, 2); MQUnifiedsensor MQ3(pin3, 2); MQUnifiedsensor MQ4(pin4, 2); MQUnifiedsensor MQ5(pin5, 2); MQUnifiedsensor MQ6(pin6, 2); MQUnifiedsensor MQ7(pin7, 2); MQUnifiedsensor MQ8(pin8, 2); MQUnifiedsensor MQ9(pin9, 2); unsigned long contador = 0; void setup() { //Init serial port Serial.begin(115200); //init the sensor MQ2.inicializar(); MQ3.inicializar(); MQ4.inicializar(); MQ5.inicializar(); MQ6.inicializar(); MQ7.inicializar(); MQ8.inicializar(); MQ9.inicializar(); //Print in serial monitor Serial.print("MQ2 to MQ9 - Calibracion"); Serial.print("Note - Make sure you are in a clean room and the sensor has pre-heated almost 4 hours"); Serial.print("Autonumeric, lecture"); } void loop() { //Read the sensor and print in serial port int lecture2 = MQ2.calibrate(); int lecture3 = MQ3.calibrate(); int lecture4 = MQ4.calibrate(); int lecture5 = MQ5.calibrate(); int lecture6 = MQ6.calibrate(); int lecture7 = MQ7.calibrate(); int lecture8 = MQ8.calibrate(); int lecture9 = MQ9.calibrate(); //Print in serial monitor Serial.print(String(contador) + ","); Serial.println(String(lecture2) + ","; Serial.println(String(lecture3) + ","; Serial.println(String(lecture4) + ","; Serial.println(String(lecture5) + ","; Serial.println(String(lecture6) + ","; Serial.println(String(lecture7) + ","; Serial.println(String(lecture8) + ","; Serial.println(String(lecture9) + ","; //Increment counter contador++; //Wait to measure next sample delay(400); }