/* MQUnifiedsensor Library - reading an MQ135 Demonstrates the use a MQ135 sensor. Library originally added 01 may 2019 by Miguel A Califa, Yersson Carrillo, Ghiordy Contreras, Mario Rodriguez Added example modified 20 March 2022 by Miguel Califa Wiring: https://github.com/miguel5612/MQSensorsLib_Docs/blob/master/static/img/MQ_Arduino.PNG Please make sure arduino A0 pin represents the analog input configured on #define pin This example code is in the public domain. Library link https://github.com/adafruit/Adafruit_ADS1X15 */ #include #include //Include the library #include //Definitions #define placa "Arduino UNO" #define type "MQ-135" //MQ135 #define RatioMQ135CleanAir 3.6//RS / R0 = 3.6 ppm float factorEscala = 0.1875F; //#define calibration_button 13 //Pin to calibrate your sensor //Declare Sensor MQUnifiedsensor MQ135(placa, type); // Crear objeto de la clase Adafruit_ADS1115 ads; void setup(void) { //Init the serial port communication - to debug the library Serial.begin(9600); //Init serial port delay(200); //Set math model to calculate the PPM concentration and the value of constants MQ135.setRegressionMethod(1); //_PPM = a*ratio^b /************************************************************************************/ MQ135.init(); // Iniciar el ADS1115 ads.begin(); Serial.print("Calibrating please wait."); float calcR0 = 0; for(int i = 1; i<=10; i ++) { // Obtener datos del A0 del ADS1115 short adc0 = ads.readADC_SingleEnded(0); float voltios = (adc0 * factorEscala)/1000.0; MQ135.externalADCUpdate(voltios); // Update data, the arduino will read the voltage from the analog pin calcR0 += MQ135.calibrate(RatioMQ135CleanAir); Serial.print("."); } MQ135.setR0(calcR0/10); Serial.println(" done!."); if(isinf(calcR0)) {Serial.println("Warning: Conection issue, R0 is infinite (Open circuit detected) please check your wiring and supply"); while(1);} if(calcR0 == 0){Serial.println("Warning: Conection issue found, R0 is zero (Analog pin shorts to ground) please check your wiring and supply"); while(1);} /***************************** MQ CAlibration ********************************************/ Serial.println("** Values from MQ-135 ****"); Serial.println("| CO | Alcohol | CO2 | Toluen | NH4 | Aceton |"); } void loop() { // Obtener datos del A0 del ADS1115 short adc0 = ads.readADC_SingleEnded(0); float voltios = (adc0 * factorEscala)/1000.0; MQ135.externalADCUpdate(voltios); // Update data, the arduino will read the voltage from the analog pin MQ135.setA(605.18); MQ135.setB(-3.937); // Configure the equation to calculate CO concentration value float CO = MQ135.readSensor(); // Sensor will read PPM concentration using the model, a and b values set previously or from the setup MQ135.setA(77.255); MQ135.setB(-3.18); //Configure the equation to calculate Alcohol concentration value float Alcohol = MQ135.readSensor(); // SSensor will read PPM concentration using the model, a and b values set previously or from the setup MQ135.setA(110.47); MQ135.setB(-2.862); // Configure the equation to calculate CO2 concentration value float CO2 = MQ135.readSensor(); // Sensor will read PPM concentration using the model, a and b values set previously or from the setup MQ135.setA(44.947); MQ135.setB(-3.445); // Configure the equation to calculate Toluen concentration value float Toluen = MQ135.readSensor(); // Sensor will read PPM concentration using the model, a and b values set previously or from the setup MQ135.setA(102.2 ); MQ135.setB(-2.473); // Configure the equation to calculate NH4 concentration value float NH4 = MQ135.readSensor(); // Sensor will read PPM concentration using the model, a and b values set previously or from the setup MQ135.setA(34.668); MQ135.setB(-3.369); // Configure the equation to calculate Aceton concentration value float Aceton = MQ135.readSensor(); // Sensor will read PPM concentration using the model, a and b values set previously or from the setup Serial.print("| "); Serial.print(CO); Serial.print(" | "); Serial.print(Alcohol); // Note: 200 Offset for CO2 source: https://github.com/miguel5612/MQSensorsLib/issues/29 /* Motivation: We have added 200 PPM because when the library is calibrated it assumes the current state of the air as 0 PPM, and it is considered today that the CO2 present in the atmosphere is around 400 PPM. https://www.lavanguardia.com/natural/20190514/462242832581/concentracion-dioxido-cabono-co2-atmosfera-bate-record-historia-humanidad.html */ Serial.print(" | "); Serial.print(CO2 + 400); Serial.print(" | "); Serial.print(Toluen); Serial.print(" | "); Serial.print(NH4); Serial.print(" | "); Serial.print(Aceton); Serial.println(" |"); /* Exponential regression: GAS | a | b CO | 605.18 | -3.937 Alcohol | 77.255 | -3.18 CO2 | 110.47 | -2.862 Toluen | 44.947 | -3.445 NH4 | 102.2 | -2.473 Aceton | 34.668 | -3.369 */ delay(500); //Sampling frequency }