2020-03-29 21:45:42 -05:00

125 lines
5.4 KiB
C++

/*
MQUnifiedsensor Library - reading an MQ135
Demonstrates the use a MQ135 sensor.
Library originally added 01 may 2019
by Miguel A Califa, Yersson Carrillo, Ghiordy Contreras, Mario Rodriguez
Added example
modified 23 May 2019
by Miguel Califa
Updated library usage
modified 26 March 2020
by Miguel Califa
Wiring:
https://github.com/miguel5612/MQSensorsLib_Docs/blob/master/static/img/MQ_Arduino.PNG
Please take care, arduino A0 pin represent the analog input configured on #define pin
This example code is in the public domain.
*/
//Include the library
#include <MQUnifiedsensor.h>
//Definitions
#define placa "Arduino UNO"
#define Voltage_Resolution 5
#define pin A0 //Analog input 0 of your arduino
#define type "MQ-135" //MQ135
#define ADC_Bit_Resolution 10 // For arduino UNO/MEGA/NANO
#define RatioMQ135CleanAir 3.6//RS / R0 = 3.6 ppm
//#define calibration_button 13 //Pin to calibrate your sensor
//Declare Sensor
MQUnifiedsensor MQ135(placa, Voltage_Resolution, ADC_Bit_Resolution, pin, type);
void setup() {
//Init the serial port communication - to debug the library
Serial.begin(9600); //Init serial port
//Set math model to calculate the PPM concentration and the value of constants
MQ135.setRegressionMethod(1); //_PPM = a*ratio^b
/***************************** MQ CAlibration ********************************************/
// Explanation:
// In this routine the sensor will measure the resistance of the sensor supposing before was pre-heated
// and now is on clean air (Calibration conditions), and it will setup R0 value.
// We recomend execute this routine only on setup or on the laboratory and save on the eeprom of your arduino
// This routine not need to execute to every restart, you can load your R0 if you know the value
// Acknowledgements: https://jayconsystems.com/blog/understanding-a-gas-sensor
Serial.print("Calibrating please wait.");
float calcR0 = 0;
for(int i = 1; i<=10; i ++)
{
MQ135.update(); // Update data, the arduino will be read the voltage on the analog pin
calcR0 += MQ135.calibrate(RatioMQ135CleanAir);
Serial.print(".");
}
MQ135.setR0(calcR0/10);
Serial.println(" done!.");
if(isinf(calcR0)) {Serial.println("Warning: Conection issue founded, R0 is infite (Open circuit detected) please check your wiring and supply"); while(1);}
if(calcR0 == 0){Serial.println("Warning: Conection issue founded, R0 is zero (Analog pin with short circuit to ground) please check your wiring and supply"); while(1);}
/***************************** MQ CAlibration ********************************************/
/*
//If the RL value is different from 10K please assign your RL value with the following method:
MQ135.setRL(10);
*/
MQ135.init();
/***************************** MQ Init ********************************************/
//Input: setup flag, if this function are on setup will print the headers (Optional - Default value: False)
//Output: print on serial port the information about sensor and sensor readings
//Remarks: Configure the pin of arduino as input.
/************************************************************************************/
Serial.println("** Lectures from MQ-135 ****");
Serial.println("| CO | Alcohol | CO2 | Tolueno | NH4 | Acteona |");
}
void loop() {
MQ135.update(); // Update data, the arduino will be read the voltage on the analog pin
MQ135.setA(605.18); MQ135.setB(-3.937); // Configurate the ecuation values to get CO concentration
float CO = MQ135.readSensor(); // Sensor will read PPM concentration using the model and a and b values setted before or in the setup
MQ135.setA(77.255); MQ135.setB(-3.18); // Configurate the ecuation values to get Alcohol concentration
float Alcohol = MQ135.readSensor(); // Sensor will read PPM concentration using the model and a and b values setted before or in the setup
MQ135.setA(110.47); MQ135.setB(-2.862); // Configurate the ecuation values to get CO2 concentration
float CO2 = MQ135.readSensor(); // Sensor will read PPM concentration using the model and a and b values setted before or in the setup
MQ135.setA(44.947); MQ135.setB(-3.445); // Configurate the ecuation values to get Tolueno concentration
float Tolueno = MQ135.readSensor(); // Sensor will read PPM concentration using the model and a and b values setted before or in the setup
MQ135.setA(102.2 ); MQ135.setB(-2.473); // Configurate the ecuation values to get NH4 concentration
float NH4 = MQ135.readSensor(); // Sensor will read PPM concentration using the model and a and b values setted before or in the setup
MQ135.setA(34.668); MQ135.setB(-3.369); // Configurate the ecuation values to get Acetona concentration
float Acetona = MQ135.readSensor(); // Sensor will read PPM concentration using the model and a and b values setted before or in the setup
Serial.print("| "); Serial.print(CO);
Serial.print(" | "); Serial.print(Alcohol);
Serial.print(" | "); Serial.print(CO2);
Serial.print(" | "); Serial.print(Tolueno);
Serial.print(" | "); Serial.print(NH4);
Serial.print(" | "); Serial.print(Acetona);
Serial.println(" |");
/*
Exponential regression:
GAS | a | b
CO | 605.18 | -3.937
Alcohol | 77.255 | -3.18
CO2 | 110.47 | -2.862
Tolueno | 44.947 | -3.445
NH4 | 102.2 | -2.473
Acetona | 34.668 | -3.369
*/
delay(500); //Sampling frequency
}