2016-04-01 17:29:48 -06:00
|
|
|
/*
|
|
|
|
* Author: Jon Trulson <jtrulson@ics.com>
|
|
|
|
* Copyright (c) 2016 Intel Corporation.
|
|
|
|
*
|
|
|
|
* Permission is hereby granted, free of charge, to any person obtaining
|
|
|
|
* a copy of this software and associated documentation files (the
|
|
|
|
* "Software"), to deal in the Software without restriction, including
|
|
|
|
* without limitation the rights to use, copy, modify, merge, publish,
|
|
|
|
* distribute, sublicense, and/or sell copies of the Software, and to
|
|
|
|
* permit persons to whom the Software is furnished to do so, subject to
|
|
|
|
* the following conditions:
|
|
|
|
*
|
|
|
|
* The above copyright notice and this permission notice shall be
|
|
|
|
* included in all copies or substantial portions of the Software.
|
|
|
|
*
|
|
|
|
* THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
|
|
|
|
* EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF
|
|
|
|
* MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
|
|
|
|
* NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE
|
|
|
|
* LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION
|
|
|
|
* OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION
|
|
|
|
* WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
|
|
|
|
*/
|
|
|
|
#pragma once
|
|
|
|
|
|
|
|
#include <string>
|
|
|
|
#include <map>
|
|
|
|
|
2016-04-25 14:27:51 -07:00
|
|
|
#include "bacnetmstp.hpp"
|
2016-06-10 12:32:54 -06:00
|
|
|
#include "bacnetutil.hpp"
|
2016-04-01 17:29:48 -06:00
|
|
|
|
|
|
|
namespace upm {
|
|
|
|
|
|
|
|
/**
|
|
|
|
* @brief E50HX Energy Meter
|
|
|
|
* @defgroup e50hx libupm-e50hx
|
|
|
|
* @ingroup uart electric
|
|
|
|
*/
|
|
|
|
|
|
|
|
/**
|
|
|
|
* @library e50hx
|
|
|
|
* @sensor e50hx
|
|
|
|
* @comname UPM API for the Veris E50HX Energy Meters
|
|
|
|
* @type electic
|
|
|
|
* @man veris
|
|
|
|
* @con uart
|
|
|
|
* @web http://www.veris.com/Item/E50H5.aspx
|
|
|
|
*
|
|
|
|
* @brief UPM API for the Veris E50HX Energy Meter
|
|
|
|
*
|
|
|
|
* This module implements support for the Veris E50H2 and E50H5
|
|
|
|
* BACnet Energy Meters.
|
|
|
|
*
|
|
|
|
* From the datasheet: The E50H5 BACnet MS/TP DIN Rail Meter with
|
|
|
|
* Data Logging combines exceptional performance and easy
|
|
|
|
* installation to deliver a cost-effective solution for power
|
|
|
|
* monitoring applications. Native serial communication via BACnet
|
|
|
|
* MS/TP provides complete accessibility of all measurements to your
|
|
|
|
* Building Automation System The data logging capability protects
|
|
|
|
* data in the event of a power failure. The E50H5 can be easily
|
|
|
|
* installed on standard DIN rail, surface mounted or contained in
|
|
|
|
* an optional NEMA 4 enclosure, as needed. The front-panel LCD
|
|
|
|
* display makes device installation and setup easy and provides
|
|
|
|
* local access to the full set of detailed measurements.
|
|
|
|
*
|
|
|
|
* This module was developed using the upm::BACNETMSTP module, based
|
|
|
|
* on libbacnet-stack 0.8.3. Both libbacnet 0.8.3 and the
|
|
|
|
* upm::BACNETMSTP libraries must be present in order to build this
|
|
|
|
* module. This driver was developed on the E50H5. The Trend Log
|
|
|
|
* functionality is not currently supported.
|
|
|
|
*
|
|
|
|
* The Binary Input Objects are also not supported as these are only
|
|
|
|
* used for the Alarm bits which are already available from Analog
|
|
|
|
* Input Object 52 as an alarm bitfield incorporating all of the
|
|
|
|
* supported alarm indicators.
|
|
|
|
*
|
|
|
|
* It was connected using an RS232->RS485 interface. You cannot use
|
|
|
|
* the built in MCU TTL UART pins for accessing this device -- you
|
|
|
|
* must use a full Serial RS232->RS485 or USB-RS485 interface
|
|
|
|
* connected via USB.
|
|
|
|
*
|
|
|
|
* @snippet e50hx.cxx Interesting
|
|
|
|
*/
|
|
|
|
|
2016-06-10 12:32:54 -06:00
|
|
|
class E50HX : public BACNETUTIL {
|
2016-04-01 17:29:48 -06:00
|
|
|
public:
|
|
|
|
|
|
|
|
// Supported Analog Value Objects. These are readable and writable.
|
|
|
|
typedef enum : uint32_t {
|
|
|
|
AV_Config = 1, // always returns 0 on read
|
|
|
|
AV_System_Type = 2,
|
|
|
|
AV_CT_Ratio_Primary = 3,
|
|
|
|
AV_CT_Ratio_Secondary = 4,
|
|
|
|
AV_PT_Ratio = 5,
|
|
|
|
AV_System_Voltage = 6,
|
|
|
|
AV_Display_Units = 7,
|
|
|
|
AV_Phase_Loss_Voltage_Threshold = 8,
|
|
|
|
AV_Phase_Loss_Imbalance_Threshold = 9,
|
|
|
|
AV_Subintervals = 10,
|
|
|
|
AV_Subinterval_Length = 11
|
|
|
|
} ANALOG_VALUES_T;
|
|
|
|
|
|
|
|
// Supported Analog Input Objects. These are read only.
|
|
|
|
typedef enum : uint32_t {
|
|
|
|
AI_Energy = 1,
|
|
|
|
AI_kW_Total = 2,
|
|
|
|
AI_kVAR_Total = 3,
|
|
|
|
AI_kVA_Total = 4,
|
|
|
|
AI_PF_Total = 5,
|
|
|
|
AI_Volts_LL_Avg = 6,
|
|
|
|
AI_Volts_LN_Avg = 7,
|
|
|
|
AI_Current_Avg = 8,
|
|
|
|
AI_kW_A = 9,
|
|
|
|
AI_kW_B = 10,
|
|
|
|
AI_kW_C = 11,
|
|
|
|
AI_PF_A = 12,
|
|
|
|
AI_PF_B = 13,
|
|
|
|
AI_PF_C = 14,
|
|
|
|
AI_Volts_AB = 15,
|
|
|
|
AI_Volts_BC = 16,
|
|
|
|
AI_Volts_AC = 17,
|
|
|
|
AI_Volts_AN = 18,
|
|
|
|
AI_Volts_BN = 19,
|
|
|
|
AI_Volts_CN = 20,
|
|
|
|
AI_Current_A = 21,
|
|
|
|
AI_Current_B = 22,
|
|
|
|
AI_Current_C = 23,
|
|
|
|
// AI24 is reserved
|
|
|
|
AI_Frequency = 25,
|
|
|
|
AI_kVAh = 26, // units = kVAh, not kWH
|
|
|
|
AI_kVARh = 27, // units = kVAh, not kWH
|
|
|
|
AI_kVA_A = 28,
|
|
|
|
AI_kVA_B = 29,
|
|
|
|
AI_kVA_C = 30,
|
|
|
|
AI_kVAR_A = 31,
|
|
|
|
AI_kVAR_B = 32,
|
|
|
|
AI_kVAR_C = 33,
|
|
|
|
AI_KW_Present_Demand = 34,
|
|
|
|
AI_KVAR_Present_Demand = 35,
|
|
|
|
AI_KWA_Present_Demand = 36,
|
|
|
|
AI_KW_Max_Demand = 37,
|
|
|
|
AI_KVAR_Max_Demand = 38,
|
|
|
|
AI_KVA_Max_Demand = 39,
|
|
|
|
AI_Pulse_Count_1 = 40, // H2 & H5
|
|
|
|
// AI41 is reserved on H2 variant
|
|
|
|
AI_Pulse_Count_2 = 41, // only on H5 variant
|
|
|
|
AI_KWH_A = 42,
|
|
|
|
AI_KWH_B = 43,
|
|
|
|
AI_KWH_C = 44,
|
|
|
|
AI_Max_Power = 45, // theoretical max power
|
|
|
|
// AI46 reserved
|
|
|
|
AI_Energy_Resets = 47,
|
|
|
|
// AI48 and AI49 reserved
|
|
|
|
AI_Power_Up_Count = 50,
|
|
|
|
AI_Output_Config = 51, // H2 = 11, H5 = 10
|
|
|
|
AI_Alarm_Bitmap = 52
|
|
|
|
} ANALOG_INPUTS_T;
|
|
|
|
|
|
|
|
// Alarm bits (AI52)
|
|
|
|
typedef enum : uint16_t {
|
|
|
|
ALARM_Volts_Error_A = 0x0001,
|
|
|
|
ALARM_Volts_Error_B = 0x0002,
|
|
|
|
ALARM_Volts_Error_C = 0x0004,
|
|
|
|
|
|
|
|
ALARM_Current_Error_A = 0x0008,
|
|
|
|
ALARM_Current_Error_B = 0x0010,
|
|
|
|
ALARM_Current_Error_C = 0x0020,
|
|
|
|
|
|
|
|
ALARM_Frequency_Error = 0x0040,
|
|
|
|
|
|
|
|
ALARM_Reserved_0 = 0x0080, // reserved
|
|
|
|
|
|
|
|
ALARM_Phase_Loss_A = 0x0100,
|
|
|
|
ALARM_Phase_Loss_B = 0x0200,
|
|
|
|
ALARM_Phase_Loss_C = 0x0400,
|
|
|
|
|
|
|
|
ALARM_Power_Factor_A = 0x0800,
|
|
|
|
ALARM_Power_Factor_B = 0x1000,
|
|
|
|
ALARM_Power_Factor_C = 0x2000,
|
|
|
|
|
|
|
|
ALARM_RTC_RESET = 0x4000 // H5 only
|
|
|
|
} ALARM_BITS_T;
|
|
|
|
|
|
|
|
// valid config values to write to AV1
|
|
|
|
typedef enum {
|
|
|
|
CFG_CLR_ENERGY_ACCUM = 30078, // clear energy accumulators
|
|
|
|
CFG_NEW_DSI = 21211, // begin new demand subinterval
|
|
|
|
CFG_RESET_MAX_TO_PRESENT = 21212, // reset max vals to present vals
|
|
|
|
CFG_CLEAR_PULSE_COUNTERS = 16498 // clear the pulse counters
|
|
|
|
} CFG_VALUES_T;
|
|
|
|
|
|
|
|
// system type configuration
|
|
|
|
typedef enum {
|
|
|
|
SYSTYPE_SINGLE_PHASE_AN = 10,
|
|
|
|
SYSTYPE_SINGLE_PHASE_AB = 11,
|
|
|
|
SYSTYPE_SPLIT_PHASE_ABN = 12,
|
|
|
|
SYSTYPE_3PHASE_ABC = 31,
|
|
|
|
SYSTYPE_3PHASE_ABCN = 40
|
|
|
|
} SYSTEM_TYPES_T;
|
|
|
|
|
|
|
|
// CT input ratio
|
|
|
|
typedef enum {
|
|
|
|
CT_RATIO_SECONDARY_1 = 1, // CT's w/ 1v outputs
|
|
|
|
CT_RATIO_SECONDARY_3 = 3 // CT's w/ 0.3v outputs
|
|
|
|
} CT_SECONDARY_T;
|
|
|
|
|
|
|
|
// LCD display units
|
|
|
|
typedef enum {
|
|
|
|
DISP_UNITS_IEC = 0, // IEC display units
|
|
|
|
DISP_UNITS_IEEE = 1 // IEEE display units
|
|
|
|
} DISP_UNITS_T;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* E50HX constructor
|
|
|
|
*
|
|
|
|
* @param targetDeviceObjectID the unique Instance ID of the
|
|
|
|
* Device Object. This number is used to uniquely identify
|
|
|
|
* devices on the BACnet network, and ranges from 1 to 4194302.
|
|
|
|
* This is not the device's MAC address, though on some devices,
|
|
|
|
* the MAC address may be used as part of this number. On the
|
|
|
|
* E50HX, this number is randomly generated per device, and you
|
|
|
|
* can see this number (or change it) on the BACnet config screens
|
|
|
|
* on the LCD.
|
|
|
|
*/
|
|
|
|
E50HX(uint32_t targetDeviceObjectID);
|
|
|
|
|
|
|
|
/**
|
|
|
|
* E50HX Destructor
|
|
|
|
*/
|
|
|
|
~E50HX();
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Write one of several 'magic' numbers to the configuration
|
|
|
|
* object (AV1). This is used to clear certain counters, reset
|
2016-06-10 12:32:54 -06:00
|
|
|
* the accumulated Energy consumption values, etc. This method
|
|
|
|
* will throw on error.
|
2016-04-01 17:29:48 -06:00
|
|
|
*
|
|
|
|
* @param config One of the CFG_VALUES_T values
|
|
|
|
*/
|
2016-06-10 12:32:54 -06:00
|
|
|
void writeConfig(CFG_VALUES_T config);
|
2016-04-01 17:29:48 -06:00
|
|
|
|
|
|
|
/**
|
|
|
|
* Set the System Type of the device. This defines the voltage
|
2016-06-10 12:32:54 -06:00
|
|
|
* lines you have connected. This method will throw on error.
|
2016-04-01 17:29:48 -06:00
|
|
|
*
|
|
|
|
* @param systype One of the SYSTEM_TYPES_T values.
|
|
|
|
*/
|
2016-06-10 12:32:54 -06:00
|
|
|
void writeSystemType(SYSTEM_TYPES_T systype);
|
2016-04-01 17:29:48 -06:00
|
|
|
|
|
|
|
/**
|
2016-06-10 12:32:54 -06:00
|
|
|
* Set the Primary CT ratio. See the datasheet for details. This
|
|
|
|
* method will throw on error.
|
2016-04-01 17:29:48 -06:00
|
|
|
*
|
|
|
|
* @param ctRatio A floating point value between 5-32000
|
|
|
|
*/
|
2016-06-10 12:32:54 -06:00
|
|
|
void writeCTRatioPrimary(float ctRatio);
|
2016-04-01 17:29:48 -06:00
|
|
|
|
|
|
|
/**
|
|
|
|
* Set the Secondary CT ratio. See the datasheet for details.
|
2016-06-10 12:32:54 -06:00
|
|
|
* This method will throw on error.
|
2016-04-01 17:29:48 -06:00
|
|
|
*
|
|
|
|
* @param ctRatio One of the CT_SECONDARY_T values.
|
|
|
|
*/
|
2016-06-10 12:32:54 -06:00
|
|
|
void writeCTRatioSecondary(CT_SECONDARY_T ctRatio);
|
2016-04-01 17:29:48 -06:00
|
|
|
|
|
|
|
/**
|
2016-06-10 12:32:54 -06:00
|
|
|
* Set the PT ratio. See the datasheet for details. This method
|
|
|
|
* will throw on error.
|
2016-04-01 17:29:48 -06:00
|
|
|
*
|
|
|
|
* @param ptRatio A floating point value between 0.01-320.0
|
|
|
|
*/
|
2016-06-10 12:32:54 -06:00
|
|
|
void writePTRatio(float ptRatio);
|
2016-04-01 17:29:48 -06:00
|
|
|
|
|
|
|
/**
|
2016-06-10 12:32:54 -06:00
|
|
|
* Set the System Voltage parmeter. See the datasheet for
|
|
|
|
* details. This method will throw on error.
|
2016-04-01 17:29:48 -06:00
|
|
|
*
|
|
|
|
* @param sysVolts A floating point value between 82.0-32000.0
|
|
|
|
*/
|
2016-06-10 12:32:54 -06:00
|
|
|
void writeSystemVoltage(float sysVolts);
|
2016-04-01 17:29:48 -06:00
|
|
|
|
|
|
|
/**
|
2016-06-10 12:32:54 -06:00
|
|
|
* Set the LCD Display Units in IEC or IEEE format. This method
|
|
|
|
* will throw on error.
|
2016-04-01 17:29:48 -06:00
|
|
|
*
|
|
|
|
* @param dispUnits One of the DISP_UNITS_T values.
|
|
|
|
*/
|
2016-06-10 12:32:54 -06:00
|
|
|
void writeDisplayUnits(DISP_UNITS_T dispUnits);
|
2016-04-01 17:29:48 -06:00
|
|
|
|
|
|
|
/**
|
|
|
|
* Set the Phase Loss Voltage Threshold. See the datasheet for
|
2016-06-10 12:32:54 -06:00
|
|
|
* details. This method will throw on error.
|
2016-04-01 17:29:48 -06:00
|
|
|
*
|
|
|
|
* @param dispUnits A floating point value between 1.0-99.0
|
|
|
|
*/
|
2016-06-10 12:32:54 -06:00
|
|
|
void writePhaseLossVT(float phaseLoss);
|
2016-04-01 17:29:48 -06:00
|
|
|
|
|
|
|
/**
|
|
|
|
* Set the Phase Loss Imbalance Threshold. See the datasheet for
|
2016-06-10 12:32:54 -06:00
|
|
|
* details. This method will throw on error.
|
2016-04-01 17:29:48 -06:00
|
|
|
*
|
|
|
|
* @param dispUnits A floating point value between 1.0-99.0
|
|
|
|
*/
|
2016-06-10 12:32:54 -06:00
|
|
|
void writePhaseLossIT(float phaseLoss);
|
2016-04-01 17:29:48 -06:00
|
|
|
|
|
|
|
/**
|
|
|
|
* Query the AI52 Object and return a bitmask of current Alarms.
|
|
|
|
* Compare against ALARM_BITS_T to determine what conditions are
|
|
|
|
* signaling an alarm. Alarm conditions will clear on their own
|
2016-06-10 12:32:54 -06:00
|
|
|
* as soon as the cause is rectified. This method will throw on
|
|
|
|
* error.
|
2016-04-01 17:29:48 -06:00
|
|
|
*
|
|
|
|
* @return A bitmask of values from ALARM_BITS_T indicating
|
|
|
|
* current alarm conditions.
|
|
|
|
*/
|
|
|
|
uint16_t getAlarmBits();
|
|
|
|
|
|
|
|
protected:
|
|
|
|
private:
|
|
|
|
};
|
|
|
|
}
|