sonar: fix sonar scan

remove utf8 characters from:
  * examples/c++/mcp9808.cxx
  * examples/c++/tmp006.cxx
  * src/bmp280/bmp280.c
  * src/max30100/max30100.c

add -j8 options to make command in scripts/sonar-scan.sh

Signed-off-by: Nicolas Oliver <dario.n.oliver@intel.com>
This commit is contained in:
Nicolas Oliver
2017-07-26 08:38:25 -07:00
committed by Mihai Tudor Panu
parent 24b6cbcc85
commit 7bee29ba62
6 changed files with 10 additions and 9 deletions

View File

@ -84,7 +84,7 @@ static int32_t _bmp280_compensate_T_int32(const bmp280_context dev,
// Returns pressure in Pa as unsigned 32 bit integer in Q24.8 format
// (24 integer bits and 8 fractional bits). Output value of
// 24674867 represents 24674867/256 = 96386.2 Pa = 963.862 hPa
// "24674867" represents 24674867/256 = 96386.2 Pa = 963.862 hPa
static uint32_t _bmp280_compensate_P_int64(const bmp280_context dev,
int32_t adc_P)
{
@ -111,7 +111,7 @@ static uint32_t _bmp280_compensate_P_int64(const bmp280_context dev,
// This function comes from the BME280 datasheet, section 4.2.3
// Returns humidity in %RH as unsigned 32 bit integer in Q22.10 format
// (22 integer and 10 fractional bits). Output value of 47445
// (22 integer and 10 fractional bits). Output value of "47445"
// represents 47445/1024 = 46.333 %RH
// BME280 only
static uint32_t _bme280_compensate_H_int32(const bmp280_context dev,
@ -135,7 +135,7 @@ static upm_result_t _read_calibration_data(const bmp280_context dev)
assert(dev != NULL);
#if defined(BMP280_USE_TEST_DATA)
printf("%s: WARNING: Test data is being used\n", __FUNCTIOM__);
printf("%s: WARNING: Test data is being used\n", __FUNCTION__);
// This data is taken from the datasheet, section 3.12
dev->dig_T1 = 27504;

View File

@ -222,7 +222,7 @@ upm_result_t max30100_get_temperature(const max30100_context* dev, float* temper
/* This register stores the fractional temperature data in increments of
* 0.0625C (1/16th of a degree C). If this fractional temperature is
* paired with a negative integer, it still adds as a positive fractional
* value (e.g., -128°C + 0.5°C = -127.5°C). */
* value (e.g., -128 C + 0.5 C = -127.5 C). */
result = max30100_read(dev, MAX30100_REG_TEMP_FRACTION, (uint8_t*)&tmp_val);
if (result != UPM_SUCCESS) return result;