6c556a9c5beaba6dabc27223d5e8c74c26aee292
Heat Exchanger Airflow Pressure Drop Calculation
Features
- Calculation of pressure drop across heat exchangers.
- Support for heat exchanger models:
- Honeywell Heat Exchanger CMM 21-50-14
- Honeywell Ram Heat Exchanger CMM 21-52-80
- Honeywell NGS Heat Exchanger CMM 47-32-06
- Honeywell NGS Regen Heat Exchanger CMM 47-32-14
- Liebherr Reheater CMM 21-53-89
- Liebherr Condenser CMM 21-53-88
- Multiple part number selection for each heat exchanger.
- Air passage configuration selection.
- Airflow and static inlet pressure measurement input.
- Automatic pass/fail evaluation against max allowed pressure drop limit.
- Recalculation support based on barometric pressure and airflow temperature.
- Logarithmic interpolation of pressure drop limits from anchor points.
- Support for KPA and PSIG pressure units.
Using
Clone and build the project:
git clone https://github.com/aZholtikov/ats0002
cd ats0002
build
Description
Heat Exchanger Airflow Pressure Drop Calculation.