Heat Exchanger Airflow Pressure Drop Calculation

Features

  1. Calculation of pressure drop across heat exchangers.
  2. Support for heat exchanger models:
    • Honeywell Heat Exchanger CMM 21-50-14
    • Honeywell Ram Heat Exchanger CMM 21-52-80
    • Honeywell NGS Heat Exchanger CMM 47-32-06
    • Liebherr Reheater CMM 21-53-89
    • Liebherr Condenser CMM 21-53-88
  3. Multiple part number selection for each heat exchanger.
  4. Air passage configuration selection.
  5. Airflow and static inlet pressure measurement input.
  6. Automatic pass/fail evaluation against max allowed pressure drop limit.
  7. Recalculation support based on barometric pressure and airflow temperature.
  8. Logarithmic interpolation of pressure drop limits from anchor points.
  9. Support for KPA and PSIG pressure units.

Using

Clone and build the project:

git clone https://github.com/aZholtikov/ats0002
cd ats0002
build
S
Description
Heat Exchanger Airflow Pressure Drop Calculation.
Readme Apache-2.0
365 KiB
0 Stars 1 Watchers 0 Forks
Languages
C 100%