154 lines
5.3 KiB
C
154 lines
5.3 KiB
C
#pragma once
|
|
|
|
#include "ats0002.h"
|
|
|
|
#ifdef __cplusplus
|
|
extern "C"
|
|
{
|
|
#endif
|
|
|
|
/**
|
|
* @file 21_53_88.h
|
|
*
|
|
* @brief Liebherr Condenser CMM 21-53-88 configuration data.
|
|
*
|
|
* This module provides static configuration data for Liebherr Condenser CMM
|
|
* 21-53-88 heat exchanger, including pressure-to-airflow anchor points for
|
|
* cooling and hot sides, air passage definitions, and heat exchanger type
|
|
* mappings for part numbers 969A0000-01 and 969A0000-02.
|
|
*
|
|
* Key features:
|
|
* - Cooling side performance data (Figure 4002)
|
|
* - Hot side performance data (Figures 4003 and 4004)
|
|
* - Complete air passage configuration with operational limits
|
|
*
|
|
* @note All data arrays are static and const-qualified for read-only access.
|
|
*/
|
|
|
|
/**
|
|
* @brief Liebherr Condenser CMM 21-53-88, Figure 4002 (P/N 969A0000-01).
|
|
*
|
|
* Cooling side dependence of ΔPS (KPA) on air flow rate (LB/MIN), UPPER line (+20%).
|
|
*/
|
|
static const airflow_to_pressure_anchors_data_t _cooling_side_969A0000_01[] = {
|
|
{25.0, 0.26},
|
|
{30.0, 0.36},
|
|
{40.0, 0.61},
|
|
{50.0, 0.91},
|
|
{60.0, 1.26},
|
|
{70.0, 1.75},
|
|
{80.0, 2.33},
|
|
{90.0, 2.80},
|
|
{100.0, 3.50},
|
|
{200.0, 13.20}};
|
|
|
|
/**
|
|
* @brief Liebherr Condenser CMM 21-53-88, Figure 4002 (P/N 969A0000-02).
|
|
*
|
|
* Cooling side dependence of ΔPS (KPA) on air flow rate (LB/MIN), UPPER line (+20%).
|
|
*/
|
|
static const airflow_to_pressure_anchors_data_t _cooling_side_969A0000_02[] = {
|
|
{25.0, 0.26},
|
|
{30.0, 0.36},
|
|
{40.0, 0.61},
|
|
{50.0, 0.91},
|
|
{60.0, 1.26},
|
|
{70.0, 1.75},
|
|
{80.0, 2.33},
|
|
{90.0, 2.80},
|
|
{100.0, 3.50},
|
|
{200.0, 13.20}};
|
|
|
|
/**
|
|
* @brief Liebherr Condenser CMM 21-53-88, Figure 4003 (P/N 969A0000-01).
|
|
*
|
|
* Hot side dependence of ΔPS (PSIG) on air flow rate (LB/MIN), UPPER line (+20%).
|
|
*/
|
|
static const airflow_to_pressure_anchors_data_t _hot_side_969A0000_01[] = {
|
|
{20.0, 0.25},
|
|
{30.0, 0.48},
|
|
{40.0, 0.80},
|
|
{50.0, 1.25},
|
|
{60.0, 1.67},
|
|
{70.0, 2.25},
|
|
{80.0, 2.75},
|
|
{90.0, 3.57},
|
|
{100.0, 4.70},
|
|
{120.0, 11.00}};
|
|
|
|
/**
|
|
* @brief Liebherr Condenser CMM 21-53-88, Figure 4004 (P/N 969A0000-02).
|
|
*
|
|
* Hot side dependence of ΔPS (PSIG) on air flow rate (LB/MIN), UPPER line (+20%).
|
|
*/
|
|
static const airflow_to_pressure_anchors_data_t _hot_side_969A0000_02[] = {
|
|
{20.0, 0.17},
|
|
{30.0, 0.34},
|
|
{40.0, 0.57},
|
|
{50.0, 0.83},
|
|
{60.0, 1.18},
|
|
{70.0, 1.56},
|
|
{80.0, 1.93},
|
|
{90.0, 2.55},
|
|
{100.0, 3.42},
|
|
{120.0, 9.51}};
|
|
|
|
static const air_passage_data_t _air_passage_969A0000_01_data[] = {
|
|
{.air_passage_description = "Cold Air Side",
|
|
.air_passage_anchors = _cooling_side_969A0000_01,
|
|
.anchors_data_size = ARRAY_SIZE(_cooling_side_969A0000_01),
|
|
.recalculated_required = false,
|
|
.airflow_pressure_unit = KPA,
|
|
.min_barometric_pressure = 840.0,
|
|
.max_barometric_pressure = 1070.0,
|
|
.min_airflow_temperature = 15.0,
|
|
.max_airflow_temperature = 33.0,
|
|
.min_airflow_pressure = 0.01,
|
|
.max_airflow_pressure = 2.0},
|
|
{.air_passage_description = "Hot Air Side",
|
|
.air_passage_anchors = _hot_side_969A0000_01,
|
|
.anchors_data_size = ARRAY_SIZE(_hot_side_969A0000_01),
|
|
.recalculated_required = false,
|
|
.airflow_pressure_unit = PSIG,
|
|
.min_barometric_pressure = 840.0,
|
|
.max_barometric_pressure = 1070.0,
|
|
.min_airflow_temperature = 15.0,
|
|
.max_airflow_temperature = 33.0,
|
|
.min_airflow_pressure = 0.01,
|
|
.max_airflow_pressure = 15.0}};
|
|
|
|
static const air_passage_data_t _air_passage_969A0000_02_data[] = {
|
|
{.air_passage_description = "Cold Air Side",
|
|
.air_passage_anchors = _cooling_side_969A0000_02,
|
|
.anchors_data_size = ARRAY_SIZE(_cooling_side_969A0000_02),
|
|
.recalculated_required = false,
|
|
.airflow_pressure_unit = KPA,
|
|
.min_barometric_pressure = 840.0,
|
|
.max_barometric_pressure = 1070.0,
|
|
.min_airflow_temperature = 15.0,
|
|
.max_airflow_temperature = 33.0,
|
|
.min_airflow_pressure = 0.01,
|
|
.max_airflow_pressure = 2.0},
|
|
{.air_passage_description = "Hot Air Side",
|
|
.air_passage_anchors = _hot_side_969A0000_02,
|
|
.anchors_data_size = ARRAY_SIZE(_hot_side_969A0000_02),
|
|
.recalculated_required = false,
|
|
.airflow_pressure_unit = PSIG,
|
|
.min_barometric_pressure = 840.0,
|
|
.max_barometric_pressure = 1070.0,
|
|
.min_airflow_temperature = 15.0,
|
|
.max_airflow_temperature = 33.0,
|
|
.min_airflow_pressure = 0.01,
|
|
.max_airflow_pressure = 15.0}};
|
|
|
|
static const heat_exchanger_type_data_t heat_exchanger_21_53_88_data[] = {
|
|
{.part_number_description = "969A0000-01",
|
|
.air_passages_data = _air_passage_969A0000_01_data,
|
|
.air_passages_data_size = ARRAY_SIZE(_air_passage_969A0000_01_data)},
|
|
{.part_number_description = "969A0000-02",
|
|
.air_passages_data = _air_passage_969A0000_02_data,
|
|
.air_passages_data_size = ARRAY_SIZE(_air_passage_969A0000_02_data)}};
|
|
|
|
#ifdef __cplusplus
|
|
}
|
|
#endif |