126 lines
5.6 KiB
Arduino
Raw Normal View History

2020-03-29 20:48:45 -05:00
/*
MQUnifiedsensor Library - reading an MQ135
Demonstrates the use a MQ135 sensor.
Library originally added 01 may 2019
by Miguel A Califa, Yersson Carrillo, Ghiordy Contreras, Mario Rodriguez
Added example
modified 23 May 2019
by Miguel Califa
Updated library usage
modified 26 March 2020
by Miguel Califa
2020-03-29 21:45:42 -05:00
Wiring:
https://github.com/miguel5612/MQSensorsLib_Docs/blob/master/static/img/MQ_Arduino.PNG
Please make sure arduino A0 pin represents the analog input configured on #define pin
2020-03-29 21:45:42 -05:00
2020-03-29 20:48:45 -05:00
This example code is in the public domain.
*/
//Include the library
#include <MQUnifiedsensor.h>
//Definitions
#define placa "Arduino UNO"
#define Voltage_Resolution 5
#define pin A0 //Analog input 0 of your arduino
#define type "MQ-135" //MQ135
#define ADC_Bit_Resolution 10 // For arduino UNO/MEGA/NANO
#define RatioMQ135CleanAir 3.6//RS / R0 = 3.6 ppm
//#define calibration_button 13 //Pin to calibrate your sensor
//Declare Sensor
MQUnifiedsensor MQ135(placa, Voltage_Resolution, ADC_Bit_Resolution, pin, type);
void setup() {
//Init the serial port communication - to debug the library
Serial.begin(9600); //Init serial port
//Set math model to calculate the PPM concentration and the value of constants
MQ135.setRegressionMethod(1); //_PPM = a*ratio^b
2020-03-30 19:17:25 -05:00
/***************************** MQ Init ********************************************/
//Remarks: Configure the pin of arduino as input.
/************************************************************************************/
MQ135.init();
/*
//If the RL value is different from 10K please assign your RL value with the following method:
MQ135.setRL(10);
*/
2020-03-29 20:48:45 -05:00
/***************************** MQ CAlibration ********************************************/
// Explanation:
// In this routine the sensor will measure the resistance of the sensor supposedly before being pre-heated
// and on clean air (Calibration conditions), setting up R0 value.
// We recomend executing this routine only on setup in laboratory conditions.
// This routine does not need to be executed on each restart, you can load your R0 value from eeprom.
2020-03-29 20:48:45 -05:00
// Acknowledgements: https://jayconsystems.com/blog/understanding-a-gas-sensor
Serial.print("Calibrating please wait.");
float calcR0 = 0;
for(int i = 1; i<=10; i ++)
{
MQ135.update(); // Update data, the arduino will read the voltage from the analog pin
2020-03-29 20:48:45 -05:00
calcR0 += MQ135.calibrate(RatioMQ135CleanAir);
Serial.print(".");
}
MQ135.setR0(calcR0/10);
Serial.println(" done!.");
if(isinf(calcR0)) {Serial.println("Warning: Conection issue, R0 is infinite (Open circuit detected) please check your wiring and supply"); while(1);}
if(calcR0 == 0){Serial.println("Warning: Conection issue found, R0 is zero (Analog pin shorts to ground) please check your wiring and supply"); while(1);}
2020-03-29 20:48:45 -05:00
/***************************** MQ CAlibration ********************************************/
Serial.println("** Values from MQ-135 ****");
Serial.println("| CO | Alcohol | CO2 | Toluen | NH4 | Aceton |");
2020-03-29 20:48:45 -05:00
}
void loop() {
MQ135.update(); // Update data, the arduino will read the voltage from the analog pin
2020-03-29 20:48:45 -05:00
MQ135.setA(605.18); MQ135.setB(-3.937); // Configure the equation to calculate CO concentration value
float CO = MQ135.readSensor(); // Sensor will read PPM concentration using the model, a and b values set previously or from the setup
2020-03-29 20:48:45 -05:00
MQ135.setA(77.255); MQ135.setB(-3.18); //Configure the equation to calculate Alcohol concentration value
float Alcohol = MQ135.readSensor(); // SSensor will read PPM concentration using the model, a and b values set previously or from the setup
2020-03-29 20:48:45 -05:00
MQ135.setA(110.47); MQ135.setB(-2.862); // Configure the equation to calculate CO2 concentration value
float CO2 = MQ135.readSensor(); // Sensor will read PPM concentration using the model, a and b values set previously or from the setup
2020-03-29 20:48:45 -05:00
MQ135.setA(44.947); MQ135.setB(-3.445); // Configure the equation to calculate Toluen concentration value
2022-03-20 12:53:36 -05:00
float Toluen = MQ135.readSensor(); // Sensor will read PPM concentration using the model, a and b values set previously or from the setup
MQ135.setA(102.2 ); MQ135.setB(-2.473); // Configure the equation to calculate NH4 concentration value
float NH4 = MQ135.readSensor(); // Sensor will read PPM concentration using the model, a and b values set previously or from the setup
2020-03-29 20:48:45 -05:00
MQ135.setA(34.668); MQ135.setB(-3.369); // Configure the equation to calculate Aceton concentration value
2022-03-20 12:53:36 -05:00
float Aceton = MQ135.readSensor(); // Sensor will read PPM concentration using the model, a and b values set previously or from the setup
2020-03-29 20:48:45 -05:00
Serial.print("| "); Serial.print(CO);
Serial.print(" | "); Serial.print(Alcohol);
2022-03-20 12:59:19 -05:00
// Note: 400 Offset for CO2 source: https://github.com/miguel5612/MQSensorsLib/issues/29
/*
Motivation:
2022-03-20 12:59:19 -05:00
We have added 400 PPM because when the library is calibrated it assumes the current state of the
air as 0 PPM, and it is considered today that the CO2 present in the atmosphere is around 400 PPM.
https://www.lavanguardia.com/natural/20190514/462242832581/concentracion-dioxido-cabono-co2-atmosfera-bate-record-historia-humanidad.html
*/
Serial.print(" | "); Serial.print(CO2 + 400);
2022-03-20 12:53:36 -05:00
Serial.print(" | "); Serial.print(Toluen);
2020-03-29 20:48:45 -05:00
Serial.print(" | "); Serial.print(NH4);
2022-03-20 12:53:36 -05:00
Serial.print(" | "); Serial.print(Aceton);
2020-03-29 20:48:45 -05:00
Serial.println(" |");
/*
Exponential regression:
GAS | a | b
CO | 605.18 | -3.937
Alcohol | 77.255 | -3.18
CO2 | 110.47 | -2.862
2022-03-20 12:53:36 -05:00
Toluen | 44.947 | -3.445
2020-03-29 20:48:45 -05:00
NH4 | 102.2 | -2.473
2022-03-20 12:53:36 -05:00
Aceton | 34.668 | -3.369
2020-03-29 20:48:45 -05:00
*/
delay(500); //Sampling frequency
}