2019-05-23 16:51:24 -05:00
|
|
|
/*
|
2019-05-23 17:00:48 -05:00
|
|
|
MQUnifiedsensor Library - reading an MQ309
|
2019-05-23 16:51:24 -05:00
|
|
|
|
2019-05-23 17:00:48 -05:00
|
|
|
Demonstrates the use a MQ309 sensor.
|
2019-05-23 16:51:24 -05:00
|
|
|
Library originally added 01 may 2019
|
|
|
|
by Miguel A Califa, Yersson Carrillo, Ghiordy Contreras, Mario Rodriguez
|
|
|
|
|
|
|
|
Added example
|
|
|
|
modified 23 May 2019
|
|
|
|
by Miguel Califa
|
|
|
|
|
2020-03-26 13:20:05 -05:00
|
|
|
Updated library usage
|
|
|
|
modified 26 March 2020
|
|
|
|
by Miguel Califa
|
|
|
|
|
2019-05-23 16:51:24 -05:00
|
|
|
This example code is in the public domain.
|
|
|
|
|
|
|
|
*/
|
|
|
|
|
|
|
|
//Include the library
|
2019-05-19 13:27:00 -05:00
|
|
|
#include <MQUnifiedsensor.h>
|
|
|
|
|
2019-05-23 16:51:24 -05:00
|
|
|
//Definitions
|
2020-03-26 13:20:05 -05:00
|
|
|
#define placa "Arduino UNO"
|
|
|
|
#define Voltage_Resolution 5
|
2019-05-23 16:51:24 -05:00
|
|
|
#define pin A0 //Analog input 0 of your arduino
|
2020-03-26 13:20:05 -05:00
|
|
|
#define type "MQ-309" //MQ309
|
|
|
|
#define ADC_Bit_Resolution 10 // For arduino UNO/MEGA/NANO
|
2019-08-15 09:02:38 -05:00
|
|
|
//#define calibration_button 13 //Pin to calibrate your sensor
|
2019-05-19 13:27:00 -05:00
|
|
|
|
2019-05-23 16:51:24 -05:00
|
|
|
//Declare Sensor
|
2020-03-26 13:20:05 -05:00
|
|
|
MQUnifiedsensor MQ309(placa, Voltage_Resolution, ADC_Bit_Resolution, pin, type);
|
2019-08-14 22:31:06 -05:00
|
|
|
|
2019-05-23 16:51:24 -05:00
|
|
|
void setup() {
|
2020-03-26 13:20:05 -05:00
|
|
|
//Init the serial port communication - to debug the library
|
2019-08-14 22:31:06 -05:00
|
|
|
Serial.begin(9600); //Init serial port
|
2019-05-19 13:27:00 -05:00
|
|
|
|
2020-03-26 13:20:05 -05:00
|
|
|
//Set math model to calculate the PPM concentration and the value of constants
|
2020-03-26 22:18:07 -05:00
|
|
|
MQ309.setRegressionMethod(1); //_PPM = a*ratio^b
|
2020-03-26 13:20:05 -05:00
|
|
|
MQ309.setA(1000000); MQ309.setB(-4.01); // Configurate the ecuation values to get CO concentration
|
|
|
|
|
2019-09-28 11:18:28 -05:00
|
|
|
/*
|
2020-03-26 13:20:05 -05:00
|
|
|
Exponential regression:
|
|
|
|
GAS | a | b
|
|
|
|
H2 | 1532.9 | -1.951
|
|
|
|
CH4 | 980.24 | -1.68
|
|
|
|
CO | 1000000 | -4.01
|
|
|
|
ALCOHOL | 473622 | -3.647
|
2019-09-28 11:18:28 -05:00
|
|
|
*/
|
2020-03-26 13:20:05 -05:00
|
|
|
|
|
|
|
// Calibration setup
|
|
|
|
MQ309.setR0(10);
|
|
|
|
|
|
|
|
/*
|
|
|
|
//If the RL value is different from 10K please assign your RL value with the following method:
|
|
|
|
MQ309.setRL(10);
|
2019-08-15 09:02:38 -05:00
|
|
|
*/
|
2019-08-14 22:31:06 -05:00
|
|
|
|
2020-03-26 13:20:05 -05:00
|
|
|
/***************************** MQ Init ********************************************/
|
|
|
|
//Remarks: Configure the pin of arduino as input.
|
|
|
|
/************************************************************************************/
|
|
|
|
MQ309.init();
|
|
|
|
/***************************** MQ Init ********************************************/
|
|
|
|
//Input: setup flag, if this function are on setup will print the headers (Optional - Default value: False)
|
|
|
|
//Output: print on serial port the information about sensor and sensor readings
|
|
|
|
//Remarks: Configure the pin of arduino as input.
|
|
|
|
/************************************************************************************/
|
|
|
|
MQ309.serialDebug(true);
|
2019-05-19 13:27:00 -05:00
|
|
|
}
|
2020-03-26 13:20:05 -05:00
|
|
|
|
|
|
|
void loop() {
|
|
|
|
MQ309.update(); // Update data, the arduino will be read the voltage on the analog pin
|
|
|
|
MQ309.readSensor(); // Sensor will read PPM concentration using the model and a and b values setted before or in the setup
|
|
|
|
MQ309.serialDebug(); // Will print the table on the serial port
|
|
|
|
delay(500); //Sampling frequency
|
|
|
|
}
|