mirror of
https://github.com/eclipse/upm.git
synced 2025-11-01 23:54:55 +03:00
JAVA: Unified Java Example names
Unified all Java examples to *match* <LIBRARY>[_otherstuf]_Example.java.
Note, a handful of the examples have a pseudo-random string for the
first component (see FlexSensor_Example.java, ideally this would be
Flex_Example.java).
This commit allows for quick development on a single sensor library
since a -DMODULE_LIST=mysensorlib now works with Java examples
(previously Java examples would fail generation when using
MODULE_LIST).
* Renamed examples
* Updated class names
* Updated library descriptor .json files
* Updated sample mapping file
TODO: Make this work like the C/C++ examples - grab the target library
name from the filename and grab all dependencies from that target
library. Fix the handful of example names which don't conform.
Signed-off-by: Noel Eck <noel.eck@intel.com>
This commit is contained in:
@@ -1,37 +1,37 @@
|
||||
{
|
||||
"Library": "max30100",
|
||||
"Description": "API for the Pulse Oximeter and Heart-Rate Sensor",
|
||||
"Sensor Class":
|
||||
{
|
||||
"MAX30100":
|
||||
{
|
||||
"Name": "Pulse Oximeter and Heart-rate Sensor",
|
||||
"Description": "The MAX30100 is an integrated pulse oximetry and heartrate monitor sensor solution. It combines two LEDs, a photodetector, optimized optics, and low-noise analog signal processing to detect pulse oximetry and heart-rate signals.",
|
||||
"Aliases": ["max30100"],
|
||||
"Categories": ["heartrate", "pulse-ox"],
|
||||
"Connections": ["i2c", "gpio"],
|
||||
"Project Type": ["medical", "wearables", "prototyping"],
|
||||
"Manufacturers": ["maxim"],
|
||||
"Kits": [],
|
||||
"Examples":
|
||||
{
|
||||
"Java": ["MAX30100_Example.java"],
|
||||
"Python": ["max30100.py"],
|
||||
"Node.js": ["max30100.js"],
|
||||
"C++": ["max30100.cxx"],
|
||||
"C": ["max30100.c"]
|
||||
},
|
||||
"Specifications":
|
||||
{
|
||||
"Operating Voltage": {"unit": "V", "low": 1.8, "high": 3.3},
|
||||
"Operating Current": {"unit": "uA", "low": 0.7, "high": 1200}
|
||||
},
|
||||
"Urls" :
|
||||
{
|
||||
"Product Pages": ["https://www.maximintegrated.com/en/products/analog/sensors-and-sensor-interface/MAX30100.html"],
|
||||
"Datasheets": ["https://datasheets.maximintegrated.com/en/ds/MAX30100.pdf"],
|
||||
"Schematics": []
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
{
|
||||
"Library": "max30100",
|
||||
"Description": "API for the Pulse Oximeter and Heart-Rate Sensor",
|
||||
"Sensor Class":
|
||||
{
|
||||
"MAX30100":
|
||||
{
|
||||
"Name": "Pulse Oximeter and Heart-rate Sensor",
|
||||
"Description": "The MAX30100 is an integrated pulse oximetry and heartrate monitor sensor solution. It combines two LEDs, a photodetector, optimized optics, and low-noise analog signal processing to detect pulse oximetry and heart-rate signals.",
|
||||
"Aliases": ["max30100"],
|
||||
"Categories": ["heartrate", "pulse-ox"],
|
||||
"Connections": ["i2c", "gpio"],
|
||||
"Project Type": ["medical", "wearables", "prototyping"],
|
||||
"Manufacturers": ["maxim"],
|
||||
"Kits": [],
|
||||
"Examples":
|
||||
{
|
||||
"Java": ["MAX30100_Example.java"],
|
||||
"Python": ["max30100.py"],
|
||||
"Node.js": ["max30100.js"],
|
||||
"C++": ["max30100.cxx"],
|
||||
"C": ["max30100.c"]
|
||||
},
|
||||
"Specifications":
|
||||
{
|
||||
"Operating Voltage": {"unit": "V", "low": 1.8, "high": 3.3},
|
||||
"Operating Current": {"unit": "uA", "low": 0.7, "high": 1200}
|
||||
},
|
||||
"Urls" :
|
||||
{
|
||||
"Product Pages": ["https://www.maximintegrated.com/en/products/analog/sensors-and-sensor-interface/MAX30100.html"],
|
||||
"Datasheets": ["https://datasheets.maximintegrated.com/en/ds/MAX30100.pdf"],
|
||||
"Schematics": []
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue