3 Commits

Author SHA1 Message Date
Noel Eck
bf425014ab python: Added upm directory for python modules
* Grouped UPM python modules into upm directory, for example:
      /usr/local/lib/python2.7/dist-packages/upm
    * Updated UPM example import statements
    * Removed unused RPATH statements from UPM src CMakeLists.txt,
      currently build collateral contains an explicit RPATH which
      is stripped from the install collateral.
    * Converted python examples to work on both python2 AND python3
    * Added ctest for loading examples w/python3
    * Removed returns from swig macros
    * UPM python module use will change...
        Before:
            import pyupm_dfrph
        After:
            from upm import pyupm_dfrph
            or
            import upm.pyupm_dfrph
            etc...
    * This commit fixes #468

Signed-off-by: Noel Eck <noel.eck@intel.com>
2016-10-13 08:22:40 -07:00
Noel Eck
2f78d9f62b python_examples: Reformatted, self-checking, executable
* Moved body of each python example to main.  This allows for basic
      load module testing for CI
    * General cleanup of python modules (crlf/tabs/prints/etc)
    * Chmod'ed to 755 to allow running examples without specifying the
      python interpreter
    * Added ctest for loading python2/3 modules
    * Added jniclasscode pragma for java swig interface files.
    * Updated check_examplenames.py module to check all languages vs. a
      cxx example name
    * Added tests for checking python module and test loading
    * Added 'make test' to travis-ci run (run ctests)
    * Print a more meaningful message when not building cxx docs into
      python modules
    * Updated check_clean.py to only check java wrapper files
    * ENABLED ctests for UPM
    * Deleted using_carrays.py python example - this is covered by other
      examples

Signed-off-by: Noel Eck <noel.eck@intel.com>
2016-10-04 16:10:17 -07:00
Jon Trulson
a8d96bd2d9 cwlsxxa: Initial implementation
The driver was developed using the Veris CWLSHTA CO2 Gas sensor.  The
'T' variant supports a temperature sensor, and the 'H' variant
supports a humidity sensor.

All 3 signals are provided by the device as analog 0-5Vdc, 0-10Vdc, or
4-20ma loop current outputs.  For devices supporting temperature, the
valid temperature range is 10C to 50C.  The humidity ranges from 0% to
100% (non-condensing).  The CO2 sensor ranges from 0 to 2000 ppm.

This driver was developed using the 5Vdc outputs and the 4-20ma
outputs.  For voltage outputs, your MCU must be configured for 5V
operation.  In addition, you must configure the sensor (via it's
configuration switches) to output 0-5VDC only.  Using any other analog
reference voltage will require the appropriate external circuitry
(such as a voltage divider) in order to interface safely with your
MCU.

In addition, the sensor can be configured for 4-20ma usage, by
specifying the correct receiver resistance (in ohms) in the
constructor.  This sensor was tested with a Cooking Hacks (Libelium)
4-channel 4-20ma Arduino interface shield.  For this interface, the
receiver resistance was specified as 165.0 ohms.

Signed-off-by: Jon Trulson <jtrulson@ics.com>